PST-1000 series Technical Manual 5 - 4
TM
CUSTOMER DISPLAY
In the following sections, it is assumed that before any command / data given
to the customer display, the PST system should have been previously prepared for
issuing command to the customer display unit through the command given under DOS
environment:
C:\> mode com1 96,n,8,1 (enter)
In other words, the protocols in RS-232C communication are listed below:
Baud Rate 9600 bps
Parity Check none
Date Bits 8
Stop Bits
1
As for the data displayed, please refer to the appendix of this manual. The
PD101 can only display numbers and decimal points in 7-segment form, and is
therefor not exhibited. The charactors displayed in PD201 and its minor variation
PD201JPN are shown in two separate pages. The fonts used in PD-2101 page 0, PD-
2101 page 1, PD-2101 EPSON emulation page 0 and PD-2101 EPSON emulation
page 1 describe PD2101. The fonts used in PD-7001 page 0, PD-7001 page 1 and
international character sets describe PD7001.
The hardware handshaking signal of the customer display is defaulted to use
CTS signal. For PST1000 series of system version B introduced in 2
nd
quarter of 1998
onward, this handshaking signal is selectable between CTS and DSR through change
of jumper setting according to the description in hardware details.